1. Applicable Scope HLC-2XT00AAC(2P/20A/120VAC)Definite Purpose Contactor (DP Contactor),For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 20A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard. |
2. Type and Meaning |
HL | C | – | 2X | T | 00 | AA | C | Company Code | Contactor | Packing Y : Individual Box Pack – : Factory Bulk Pack | 2 Pole | Coil Voltage 24VAC | Rating of current | Terminal | with cover |
|
Product Explanation And Main Technical Parameter |
Type | HLC-2XT00AAC(2P/20A/120VAC) Definite Purpose Contactor | Rating Current | Ie: 20A | Rating Voltage | Ue 240/277V | Insulation Voltage | Ui 660V | Coil Voltage | Us 120V | Mechanical Life | 1000,000 Cycle | Electrical life | 100,000 Cycle | Product Explanation | 1.Product Description HLC-2XT00AAC Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 277v, Fixed Operating Current To 20A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control. 2 .The Regular Service Conditon And Installs The Condition a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets Down The Limiting Value Is -25 b. The Installation Site Elevation Does Not Surpass 2000m c. The Air Pollution Rank Is 2 Levels d. Installs The Category Is Ii ; e. Installment Facing The Gradient Does Not Surpass ±5° f. Not Remarkable Undulation, Impact And Vibration Place. 3 .Main Technical Parameter a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably Working, Its Drop Out Voltage In 20% ~ 70%Us b. Contactor Use Category: Ac-1Ac8a c. Contactor In With 0.4m Place, Its Noise Below 40db. 4 . Installing Specification And Install Size a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5° b. Before The Use Should Inspect The Power Terminal And The Contactor Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating The Breakdown, Behind Check Off May Electrify Tries . | |
|
Conforms To The Standard |
Conforms To International Standard | 1 、Conforms To UL508, IEC60947, GB14048 Standard。 | 2 、Approved By UL,CUL,TUV,CE,CCC and ISO9001 System Certification(SGS)。 | UL Files Number: E251539 CCC Files Number: 2005010309156761 |
|
Ordering Request |
To Guarantee You Purchase Right, Please Read The Specify Type Before Order. |
Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc |
If You Request As Follows: Nominal Current: 20A, Working Voltage: 240/277V,480V,600V, Pole Number: Two Pole, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50/Each Box (Factory Packing), With The Cover. Then You May Select The Type : HLC-2XT00AAC |
Lifts The Samples As Follows (Contains Derivation Type From This Model) Rating Current (Ie) | Pole | Rating of Coil Control Voltage | Control Motor Power | 24VAC | 120VAC | 208/240VAC | 277VAC | 380/480VAC | 240VAC | 20A | 2P | HLC-2XQ00AAC | HLC-2XT00AAC | HLC-2XU00AAC | HLC-2XV00AAC | HLC-2XW00AAC | 2.5Kw |
|
评价
目前还没有评价